417 research outputs found

    A highly attenuating and frequency tailorable annular hole phononic crystal for surface acoustic waves

    Get PDF
    This is the final version of the article. Available from Springer Nature via the DOI in this record.Surface acoustic wave (SAW) devices are widely used for signal processing, sensing and increasingly for lab-on-a-chip applications. Phononic crystals can control the propagation of SAW, analogous to photonic crystals, enabling components such as waveguides and cavities. Here we present an approach for the realisation of robust, tailorable SAW phononic crystals, based on annular holes patterned in a SAW substrate. Using simulations and experiments, we show that this geometry supports local resonances which create highly attenuating phononic bandgaps at frequencies with negligible coupling of SAWs into other modes, even for relatively shallow features. The enormous bandgap attenuation is up to an order-of-magnitude larger than that achieved with a pillar phononic crystal of the same size, enabling effective phononic crystals to be made up of smaller numbers of elements. This work transforms the ability to exploit phononic crystals for developing novel SAW device concepts, mirroring contemporary progress in photonic crystals.The control and manipulation of propagating sound waves on a surface has applications in on-chip signal processing and sensing. Here, Ash et al. deviate from standard designs and fabricate frequency tailorable phononic crystals with an order-of-magnitude increase in attenuation.B.J.A. acknowledges funding from the EPSRC Centre for Doctoral Training in Metamaterials, grant number EP/L015331/1

    Multiple micronutrient supplementation improves vitamin B12 and folate concentrations of HIV infected children in Uganda: a randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The effect of multiple micronutrient supplementation on vitamin B<sub>12 </sub>and folate has hither to not been reported in African HIV infected children. This paper describes vitamin B<sub>12 </sub>and folate status of Ugandan HIV infected children aged 1-5 years and reports the effect of multiple micronutrient supplementation on serum vitamin B<sub>12 </sub>and folate concentrations.</p> <p>Methods</p> <p>Of 847 children who participated in a multiple micronutrient supplementation trial, 214 were assessed for vitamin B<sub>12 </sub>and folate concentrations pre and post supplementation. One hundred and four children were randomised to two times the recommended dietary allowance (RDA) of a 14 multiple micronutrient supplement (MMS) and 114 to a 'standard of care' supplement of 6 multivitamins (MV). Serum vitamin B<sub>12 </sub>was measured by an electrochemiluminescence immunoassay and folate by a competitive protein-binding assay using Modular E (Roche) automatic analyzer. Vitamin B<sub>12 </sub>concentrations were considered low if less than 221picomoles per litre (pmol/L) and folate if < 13.4 nanomoles per litre (nmol/L). The Wilcoxon Signed Ranks test was used to measure the difference between pre and post supplementation concentrations.</p> <p>Results</p> <p>Vitamin B<sub>12 </sub>was low in 60/214 (28%) and folate in 62/214 (29.0%) children. In the MMS group, the median concentration (IQR) of vitamin B<sub>12 </sub>at 6 months was 401.5 (264.3 - 518.8) pmol/L compared to the baseline of 285.5 (216.5 - 371.8) pmol/L, p < 0.001. The median (IQR) folate concentrations increased from 17.3 (13.5 - 26.6) nmol/L to 27.7 (21.1 - 33.4) nmol/L, p < 0.001. In the 'standard of care' MV supplemented group, the median concentration (IQR) of vitamin B<sub>12 </sub>at 6 months was 288.5 (198.8 - 391.0) pmol/L compared to the baseline of 280.0 (211.5 - 386.3) pmol/L while the median (IQR) folate concentrations at 6 months were 16.5 (11.7 - 22.1) nmol/L compared to 15.7 (11.9 - 22.1) nmol/L at baseline. There was a significant difference in the MMS group in both vitamin B<sub>12 </sub>and folate concentrations but no difference in the MV group.</p> <p>Conclusions</p> <p>Almost a third of the HIV infected Ugandan children aged 1-5 years had low serum concentrations of vitamin B<sub>12 </sub>and folate. Multiple micronutrient supplementation compared to the 'standard of care' supplement of 6 multivitamins improved the vitamin B<sub>12 </sub>and folate status of HIV infected children in Uganda.</p> <p>Trial registration</p> <p><url>http://ClinicalTrials.gov</url><a href="http://www.clinicaltrials.gov/ct2/show/NCT00122941">NCT00122941</a>)</p

    Use of a health information exchange system in the emergency care of children

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Children may benefit greatly in terms of safety and care coordination from the information sharing promised by health information exchange (HIE). While information exchange capability is a required feature of the certified electronic health record, we known little regarding how this technology is used in general and for pediatric patients specifically.</p> <p>Methods</p> <p>Using data from an operational HIE effort in central Texas, we examined the factors associated with actual system usage. The clinical and demographic characteristics of pediatric ED encounters (n = 179,445) were linked to the HIE system user logs. Based on the patterns of HIE system screens accessed by users, we classified each encounter as: no system usage, basic system usage, or novel system usage. Using crossed random effects logistic regression, we modeled the factors associated with basic and novel system usage.</p> <p>Results</p> <p>Users accessed the system for 8.7% of encounters. Increasing patient comorbidity was associated with a 5% higher odds of basic usage and 15% higher odds for novel usage. The odds of basic system usage were lower in the face of time constraints and for patients who had not been to that location in the previous 12 months.</p> <p>Conclusions</p> <p>HIE systems may be a source to fulfill users' information needs about complex patients. However, time constraints may be a barrier to usage. In addition, results suggest HIE is more likely to be useful to pediatric patients visiting ED repeatedly. This study helps fill an existing gap in the study of technological applications in the care of children and improves knowledge about how HIE systems are utilized.</p

    Acute graft versus host disease

    Get PDF
    Acute graft-versus-host disease (GVHD) occurs after allogeneic hematopoietic stem cell transplant and is a reaction of donor immune cells against host tissues. Activated donor T cells damage host epithelial cells after an inflammatory cascade that begins with the preparative regimen. About 35%–50% of hematopoietic stem cell transplant (HSCT) recipients will develop acute GVHD. The exact risk is dependent on the stem cell source, age of the patient, conditioning, and GVHD prophylaxis used. Given the number of transplants performed, we can expect about 5500 patients/year to develop acute GVHD. Patients can have involvement of three organs: skin (rash/dermatitis), liver (hepatitis/jaundice), and gastrointestinal tract (abdominal pain/diarrhea). One or more organs may be involved. GVHD is a clinical diagnosis that may be supported with appropriate biopsies. The reason to pursue a tissue biopsy is to help differentiate from other diagnoses which may mimic GVHD, such as viral infection (hepatitis, colitis) or drug reaction (causing skin rash). Acute GVHD is staged and graded (grade 0-IV) by the number and extent of organ involvement. Patients with grade III/IV acute GVHD tend to have a poor outcome. Generally the patient is treated by optimizing their immunosuppression and adding methylprednisolone. About 50% of patients will have a solid response to methylprednisolone. If patients progress after 3 days or are not improved after 7 days, they will get salvage (second-line) immunosuppressive therapy for which there is currently no standard-of-care. Well-organized clinical trials are imperative to better define second-line therapies for this disease. Additional management issues are attention to wound infections in skin GVHD and fluid/nutrition management in gastrointestinal GVHD. About 50% of patients with acute GVHD will eventually have manifestations of chronic GVHD

    The use of the CR-10 scale to allow self-regulation of isometric exercise intensity in pre-hypertensive and hypertensive participants

    Get PDF
    Purpose: Isometric exercise (IE) has been shown to lower blood pressure (BP). Using equipment with force output displays, intensity is usually regulated at 30% maximal voluntary contraction (MVC); however, the cost of programmable equipment and their requirement for maximal contractions presents limitations. A simple, cost-effective alternative deserves investigation. The purpose of this study was (i) to explore the relationship between %MVC, change in systolic BP (ΔSBP), and perceived exertion (CR-10) and (ii) to assess the validity of self-regulation of intensity during isometric handgrip exercise. Methods: Fourteen pre-hypertensive and hypertensive adults completed eight, 2-minute isometric handgrip exercises at randomised intensities; participants estimated their perceived exertion at 30-second intervals (Estimation Task). Subsequently, on three separate occasions participants performed four 2-minute contractions at an exertion level that they perceived to be equivalent to CR-10 “Level-6” (Production Task). Results: There were significant linear relationships between the estimated exertion on the CR-10 scale, and ΔSBP (r=0.784) and %MVC (r=0.845). Level 6 was equivalent to an average ΔSBP of 38mmHg (95% CI; 44mmHg, 32mmHg) and a relative force of 33% MVC (95% CI; 36.2%, 30%). During the production task, %MVC was not significantly different between the estimation task and each production task. In at least the first two repetitions of each production task, ΔSBP was significantly lower than that observed in the estimation task. Conclusion: These findings show that CR-10 “level-6” is an appropriate method of self-regulating isometric handgrip intensity; its use offers an affordable and accessible alternative for isometric exercise prescription aimed at reducing BP

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    The impact of viral mutations on recognition by SARS-CoV-2 specific T cells.

    Get PDF
    We identify amino acid variants within dominant SARS-CoV-2 T cell epitopes by interrogating global sequence data. Several variants within nucleocapsid and ORF3a epitopes have arisen independently in multiple lineages and result in loss of recognition by epitope-specific T cells assessed by IFN-γ and cytotoxic killing assays. Complete loss of T cell responsiveness was seen due to Q213K in the A∗01:01-restricted CD8+ ORF3a epitope FTSDYYQLY207-215; due to P13L, P13S, and P13T in the B∗27:05-restricted CD8+ nucleocapsid epitope QRNAPRITF9-17; and due to T362I and P365S in the A∗03:01/A∗11:01-restricted CD8+ nucleocapsid epitope KTFPPTEPK361-369. CD8+ T cell lines unable to recognize variant epitopes have diverse T cell receptor repertoires. These data demonstrate the potential for T cell evasion and highlight the need for ongoing surveillance for variants capable of escaping T cell as well as humoral immunity.This work is supported by the UK Medical Research Council (MRC); Chinese Academy of Medical Sciences(CAMS) Innovation Fund for Medical Sciences (CIFMS), China; National Institute for Health Research (NIHR)Oxford Biomedical Research Centre, and UK Researchand Innovation (UKRI)/NIHR through the UK Coro-navirus Immunology Consortium (UK-CIC). Sequencing of SARS-CoV-2 samples and collation of data wasundertaken by the COG-UK CONSORTIUM. COG-UK is supported by funding from the Medical ResearchCouncil (MRC) part of UK Research & Innovation (UKRI),the National Institute of Health Research (NIHR),and Genome Research Limited, operating as the Wellcome Sanger Institute. T.I.d.S. is supported by a Well-come Trust Intermediate Clinical Fellowship (110058/Z/15/Z). L.T. is supported by the Wellcome Trust(grant number 205228/Z/16/Z) and by theUniversity of Liverpool Centre for Excellence in Infectious DiseaseResearch (CEIDR). S.D. is funded by an NIHR GlobalResearch Professorship (NIHR300791). L.T. and S.C.M.are also supported by the U.S. Food and Drug Administration Medical Countermeasures Initiative contract75F40120C00085 and the National Institute for Health Research Health Protection Research Unit (HPRU) inEmerging and Zoonotic Infections (NIHR200907) at University of Liverpool inpartnership with Public HealthEngland (PHE), in collaboration with Liverpool School of Tropical Medicine and the University of Oxford.L.T. is based at the University of Liverpool. M.D.P. is funded by the NIHR Sheffield Biomedical ResearchCentre (BRC – IS-BRC-1215-20017). ISARIC4C is supported by the MRC (grant no MC_PC_19059). J.C.K.is a Wellcome Investigator (WT204969/Z/16/Z) and supported by NIHR Oxford Biomedical Research Centreand CIFMS. The views expressed are those of the authors and not necessarily those of the NIHR or MRC

    Relationship of edge localized mode burst times with divertor flux loop signal phase in JET

    Get PDF
    A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM
    corecore